1. Bathroom Dimensions HVI / ASHRAE 62.2
ft
ft
ft

Why a 110 CFM Fan Only Pulls 60 CFM on Crushed 4-Inch Flex Duct

The Home Ventilating Institute (HVI) sizes bathrooms under 100 sq ft at 1 CFM per square foot (minimum 50 CFM by IRC code), while larger primary suites (>100 sq ft) add 50 CFM per toilet, shower, and tub (100 CFM for jetted tubs). Equally important: any fan rated 110 CFM or higher requires a 6-inch smooth galvanized or pulled-tight insulated duct—choking it down to a 4-inch hose cuts airflow by 40% and doubles sone noise!

Frequently Asked Questions

What Sone rating is considered a quiet bathroom exhaust fan?
Look for 0.3 to 1.0 Sones (such as Panasonic WhisperCeiling DC models), which sound barely louder than a whisper. Builder-grade fans rated 3.0 to 4.0 Sones sound as loud as a box fan on high.