Bathroom Exhaust Fan CFM Chart by Room Size, Ceiling Height & Duct Length
To exchange stale, steam-saturated bathroom air 8 times per hour (8 ACH), multiply `Length × Width × Ceiling Height × 8 ÷ 60`. For standard 8-foot ceilings, that simplifies neatly to 1.07 CFM per square foot—and climbs proportionately on 9-foot and 10-foot ceilings:
| Bathroom Floor Area | 8-ft Ceiling Min CFM | 9-ft Ceiling Min CFM | 10-ft Ceiling Min CFM | Duct Diameter |
|---|---|---|---|---|
| 40 sq ft Powder / 3/4 Bath | 50 CFM | 50 – 70 CFM | 70 – 80 CFM | 4" Rigid |
| 60 sq ft Hallway Full Bath | 70 – 80 CFM | 80 CFM | 80 – 110 CFM | 4" or 6" |
| 90 sq ft Midsize Bath | 100 – 110 CFM | 110 CFM | 110 – 130 CFM | 6" Duct |
| 130+ sq ft Primary Suite | 150+ CFM (By Fixture!) | 150 – 190 CFM | 190+ CFM | 6" Insulated Rigid |
Include duct-elbow static pressure losses in our Bathroom Exhaust Fan CFM Calculator.
Run Your Exact Project Dimensions
Use our free Bathroom Fan & Range Hood CFM Calculator
Frequently Asked Questions
Can a bathroom exhaust fan vent into the attic if the attic has ridge vents?
NEVER! Dumping warm, humid shower steam into a cold attic condenses frost and liquid water directly onto roof sheathing nails, growing black attic mold within one winter. Every bath fan must terminate outdoors through an insulated duct and dampered roof or wall cap.